pyvkfft-test --systematic --backend pyopencl --gpu a40 --max-nb-tests 0 --nproc 32 --ndim 1 --range 2 10000 --bluestein --inplace --norm 1 --range-mb 0 4100 FAILURES: ====================================================================== test_systematic (backend='pyopencl', shape=(9376,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.606986e-01 ni=8.256998e-01>7.972018e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9377,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.479287e-01 ni=9.029940e-01>7.972064e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9382,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.588662e-01 ni=8.857653e-01>7.972295e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9383,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.510900e-01 ni=7.960569e-01>7.972342e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9385,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.445536e-01 ni=9.347653e-01>7.972434e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9387,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.685982e-01 ni=8.826627e-01>7.972527e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9388,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.494992e-01 ni=8.034787e-01>7.972573e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9389,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.477368e-01 ni=8.009830e-01>7.972619e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9391,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.624254e-01 ni=9.092281e-01>7.972712e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9392,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.470424e-01 ni=9.491154e-01>7.972758e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9395,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.664898e-01 ni=8.079157e-01>7.972897e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9397,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.433070e-01 ni=7.149799e-01>7.972989e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9402,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.600302e-01 ni=8.998488e-01>7.973220e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9403,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.553060e-01 ni=9.259495e-01>7.973266e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9404,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.414186e-01 ni=9.743180e-01>7.973313e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9406,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.621255e-01 ni=8.998245e-01>7.973405e-06 ====================================================================== test_systematic (backend='pyopencl', shape=(9407,), ndim=1, dtype=dtype('float32'), norm=1, use_lut=False, inplace=True, r2c=False, dct=False, fstride=False) [pyvkfft.test.test_fft.TestFFTSystematic]: ---------------------------------------------------------------------- Traceback (most recent call last): File "/home/esrf/favre/miniconda3/envs/pynx-py311-cu11.7/lib/python3.11/site-packages/pyvkfft/test/test_fft.py", line 914, in test_systematic self.assertTrue(ni < tol, "Accuracy mismatch after FFT, n2=%8e ni=%8e>%8e" % (n2, ni, tol)) AssertionError: False is not true : Accuracy mismatch after FFT, n2=8.632343e-01 ni=8.425978e-01>7.973451e-06