C INPUT PARAMETERS: C The input parameters are divided into sections related to the storage ring, C the undulator device, and the brilliance calculation. C Machine Parameters: C ENERGY Storage ring energy (GeV) C CUR Storage ring current (mA) C SIGE Energy spread (sigma(E)/E) C SIGX RMS beam size (horizontal) (mm) C SIGY RMS beam size (vertical) (mm) C SIGX1 RMS beam divergence (horizontal) (mrad) C SIGY1 RMS beam divergence (vertical) (mrad) C Undulator Parameters: C PERIOD Undulator period length (cm) C N Number of periods C Scan Parameters: C EMIN Lower energy limit for FIRST harmonic (eV) C EMAX Upper energy limit for FIRST harmonic (eV) C NE Number of energy points C IHMIN Minimum harmonic of interest C IHMAX Maximum harmonic of interest C IHSTEP Step size for the harmonics C Brilliance Parameters: C IHEL Type of device; ihel=0: regular planar, ihel=1: helical C METHOD Method C METHOD={0,1}Non-zero emittance; C infinite-N +convolution (Dejus' approach) C METHOD=2 Non-zero emittance; C infinite-N +convolution (Walker's approach) C METHOD=3 Non-zero emittance; finite-N (Walker's) C C IK Print K-values & powers; ik=0: quiet, ik=1: print C NEKS Number of energy points for peak search: Default 100, or C use 0 for default.